IRMA-International.org: Creator of Knowledge
Information Resources Management Association
Advancing the Concepts & Practices of Information Resources Management in Modern Organizations

Precision and Reliability of the T-Scan III System: Analyzing Occlusion and the Resultant Timing and Distribution of Forces in the Dental Arch

Precision and Reliability of the T-Scan III System: Analyzing Occlusion and the Resultant Timing and Distribution of Forces in the Dental Arch
View Sample PDF
Author(s): Bernd Koos, DMD (University Medical Center Schleswig-Holstein, Germany)
Copyright: 2020
Pages: 29
Source title: Handbook of Research on Clinical Applications of Computerized Occlusal Analysis in Dental Medicine
Source Author(s)/Editor(s): Robert B. Kerstein, DMD (Tufts University School of Dental Medicine, USA & Private Dental Practice Limited to Prosthodontics and Computerized Occlusal Analysis, USA)
DOI: 10.4018/978-1-5225-9254-9.ch003

Purchase


Abstract

Precise analysis of occlusal contacts and occlusal force is a problem in functional diagnostics that has not yet been satisfactorily resolved, despite the fact that the deleterious consequences of an unbalanced occlusion are widespread, and can be severe. In clinical practice, the present-day analysis of the occlusion is reduced to depicting force with color-marking foils that leave ink marks upon the teeth. However, these foils only indicate the localization of contacts, but do not describe reliably the occlusal force relationships. Precise analysis that incorporates time resolution, and plots the distribution of forces within the occlusion, is not possible when employing the traditional occlusal indicator methods. A detailed occlusal force and timing analysis can only be provided by performing a computer-assisted analysis, using the T-Scan III system (Tekscan, Inc. S. Boston, MA, USA), which records changing relative occlusal force levels and real-time occlusal contact sequence data, with high definition (HD) recording sensors. The following chapter demonstrates the accuracy and reliability of this computer-based occlusal measurement method that reliably describes the time-dependent distribution of occlusal force evolution.

Related Content

Tungki Pratama Umar, Andrei Tanasov, Bella Stevanny, Dessy Agustini, Tirth Dave, Ayman Nabhan, Maysa Madany, Muiz Ibrahim, Dang Nguyen, Shivani Jain, Nityanand Jain. © 2024. 39 pages.
Murtala Ismail Adakawa, N. S. Harinarayana, Elizaveta Vitalievna Sokolova. © 2024. 37 pages.
Suchismita Satapathy, Hullash Chauhan, Debesh Mishra. © 2024. 24 pages.
Ahmed Chemseddine Bouarar, Dachel Martínez Asanza, Smail Mouloudj, Achouak Bouarar, Kamel Mouloudj, Majedeh Bozorgi. © 2024. 16 pages.
S M Nazmuz Sakib. © 2024. 27 pages.
Murtala Ismail Adakawa, Elizaveta Vitalievna Sokolova, N. S. Harinarayana. © 2024. 30 pages.
Dachel Martínez Asanza, Isis Anastasia Rojas Herrera, Anuli U. Njoku, Ana Clara Reyes Puig, Farida Mouloudj, Indira Gómez Capote, Gerardo Maupome. © 2024. 18 pages.
Body Bottom